TABLE OF CONTENTS

UL LISTINGS
WARNINGS AND PRECAUTIONS
ELITE RECOMMENDED SETUP
CONCRETE PAD & GATE ARM ATTACHMENT
INSTALLATION LAYOUTS
COMPACT INSTALLATION
GATE ARM INSTALLATION
ADJUSTMENT OF OUTPUT SHAFT & GATE TRAVELING DISTANCE
CHOOSING MOVEMENT DIRECTION
HOW TO CONNECT POWER 120V
CLUTCH ADJUSTMENT
WARNING SIGNS
TWO-WAY ADJUSTABLE REVERSING SENSOR
ADJUSTABLE TIMER
MASTER & SLAVE WITH TIMER ON
MASTER & SLAVE WITH TIMER OFF
OPERATING INSTRUCTIONS FOR OPTIONAL SYSTEMS
MASTER AND SLAVE WITH OPTIONAL BOARD
SOLENOID CONNECTION WITH OPTIONAL BOARD
MAGLOCK CONNECTION WITH OPTIONAL BOARD
SOLENOID/MAGLOCK J3 STANDARD CONNECTION
HOUSE ALARM/PROXIMITY SWITCH CONNECTIONS
OPTIONAL BUILT-IN LOOP DETECTOR
THREE PUSH BUTTON STATION
TERMINAL INPUT CONNECTIONS
SAFETY LOOP SYSTEM / CENTER LOOP SYSTEM 
EXIT LOOP SYSTEM
EMERGENCY RELEASE
HOW TO REPLACE CONTROL BOARD
AUDIO ALARM
OPTIONAL DC-1000U BACK-UP
RESET BUTTON / STOP BUTTON
UPHILL DRIVEWAY INSTALLATION
SECONDARY ENTRAPMENT WIRING
SECONDARY ENTRAPMENT MOUNTING
TROUBLESHOOTING / LED INFORMATION CENTER
TROUBLESHOOTING TABLE
CSW-200 PARTS ILLUSTRATIONS
LIST OF CSW-200 PARTS / MAINTENANCE

     

UL LISTINGS AND INSTRUCTIONS

INSTALLATION INSTRUCTIONS REGARDING THE GATE OPERATOR

A) Install the gate operator only when:

1) The operator is appropriate for the construction and the usage Class of the gate.

2) All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet (1.2 m) above the ground to prevent a 2 1/4inch (57.15 mm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position.

3) All exposed pinch points are eliminated or guarded, and

4) Guarding is supplied for exposed rollers.

B) The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening.

C) The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas.

D) The gate must be properly installed and work freely in both directions prior to the installation of the gate operator.
E) -

F) Controls must be far enough from the gate so that the user is prevented from coming in contact with the gate while operating the controls. Controls intended to be used to reset an operator after 2 sequential activations of the entrapment protection device or devices must be located in the line of sight of the outdoor gate or easily accessible controls shall have a security feature to prevent unauthorized use.

G) All warning signs and placards must be installed where visible in the area of the gate.

H) For a gate operator utilizing a non-contact sensor such as a photo beam:

1) See instructions on the placement of non-contact sensor for each Type of application,

2) Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate still moving, and

3) One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a moving gate or barrier.

1) For a gate operator utilizing a contact sensor such as an edge sensor:

1) One or more contact sensors shall be located at the leading edge, trailing edge and postmounted both inside and outside of a vehicular horizontal slide gate.

2) One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate.

3) One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate.

4) A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subjected to mechanical damage.

5) A wireless contact sensor such as the one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction. A wireless contact sensor shall function under the intended end-use conditions.

TOP

IMPORTANT SAFETY INSTRUCTIONS

WARNING - To reduce the risk of injury or death:

1. READ AND FOLLOW ALL INSTRUCTIONS.

2. Never let children operate or play with gate controls. Keep the remote control away from children.

3. Always keep people and objects away from the gate while the gate is in operation. NO ONE SHOULD CROSS THE PATH OF A MOVING GATE.

4. Test the gate operator monthly. The gate MUST reverse on contact with a rigid object or stop when an object activates the non-contact sensors. After adjusting the force or the limit of travel, retest the gate operator, Failure to adjust and retest the gate operator properly can increase the risk of injury or death.

5. Use the emergency release only when the gate is not moving. Make sure the power for the gate operator is off.
6. KEEP GATES PROPERLY MAINTAINED. Read the manual. Have a qualified service person make repairs to the gate or gate hardware.

7. The entrance is for vehicles only. Pedestrians must use separate entrance.

8. SAVE THESE INSTRUCTIONS.

Gate - A moving barrier such as a swinging, sliding, raising lowering, rolling, or like, barrier, that is a stand-alone passage barrier or is that portion of a wall or fence system that controls entrance and/or egress by persons or vehicles and completes the perimeter of a defined area.
Vehicular horizontal slide-gate operator (or system) - A vehicular gate operator (or system) that controls a gate which slides in a horizontal direction that is intended for use for vehicular entrance or exit to a drive, parking lot, or the like.

Residential vehicular gate operator - Class I - A vehicular gate operator (or system) intended for use in a home of one-to four single family dwelling, or a or garage or parking area associated therewith.
Commercial/General access vehicular gate operator Class 11 - A vehicular gate operator (or system) intended for use in a commercial location or building such as a multi-family housing unit (five or more single family units) hotel, garages, retail store or other building servicing the general public.

Commercial/General access vehicular gate operator Class III - A vehicular gate operator (or system) intended for use in a industrial location or building such as a factory or loading dock area or other locations not intended to service the
Al general public.
Restricted access vehicular gate operator Class IV A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel.

TOP

WARNINGS AND PRECAUTIONS

The CSW-200 is for vehicular gate use only!!
Note for use on any Pedestrian: Gateways, Doorways or Passageways

Owners must never let pedestrians cross the path, step or hang on any moving gate!

ELITE RECOMMENDED SETUP

Recommended Gate Setup Configuration
Pedestrians Must have a Separate Walkway!

CSW-200-UL 
1/2 hp Motor, 120 VAC, 4 amp.
Maximum Gate Length - 18 ft. 
Maximum Gate Weight - 600 lbs. 
CSW-200-UL-OM
  Two-1/2 hip Motors, 120 VAC, 4 amp.
Maximum Gate Length - 18 ft.
Maximum Gate Weight - 800 lbs.
CSW-200-UL-ST 
1/2 hp Motor, 120 VAC, 4 amp. 
Maximum Gate Length - 18 ft.
Maximum Gate Weight - 600 lbs.  
CSW-200-UL-1HP
Two-1/2 hip Motors, 120 VAC, 7.9 amps.
Maximum Gate Length - 20 ft.
Maximum Gate Weight - 1000 lbs.

Be sure to read and follow all Elite and UL instructions before installing and operating any Elite products. Elite Access Systems, Inc. is not responsible for improper installations or failure to comply with local building codes.

TOP


CONCRETE PAD AND GATE ATTACHMENT

INSTALLATION LAYOUTS

Dimension (A) thru (E) are from the center of one pivot point to the center of another pivot point.

Caution: If the gate is longer than 18 feel, follow Chart A : A-2.
Suggestion: The dimension between the gate and the concrete pad is always 10 inches less than the dimension D.
Example: D = 42", if the dimension between the gate and the concrete pad is 32
*Note - If this dimension is between 20 and 32 inches, compact installation is necessary (refer to page 10).

TOP

 

COMPACT INSTALLATION

Compact installation only!
Do not use these measurements on a Standard Installation

Follow the exact measurements, then cut the standard arm to meet the shorter measurements.

TOP

 

GATE ARM INSTALLATION

Weld completely around the rectangular tubes

TOP

 

ADJUSTMENT OF OUTPUT SHAFT
ADJUSTING GATE TRAVELING DISTANCE
Pull the short arm away from the gate. NO slippage should occur. If it does, go back and tighten the nut more.

Release the red handle and open the gate to a distance desired. Loosen the screw. Turn plastic part until the half moon shape hits the limit switch. For closing cycle, do the same with the other plastic part.

For a more precise adjustment, you may use the set allen screw.

TOP


CHOOSING MOVEMENT DIRECTION

HOW TO CONNECT POWER

16 gauge 14 gauge 12 gauge 10 gauge 8 gauge 4 gauge
150 ft 250 ft 400 ft 650 ft 1000 ft 2200 ft
CAUTION:  Elite Access Systems Inc. is not responsible for conflicts between the information listed above and the requirements of your local building codes. The information is intended for suggested use. Check your local codes before installation.

TOP

 

CLUTCH ADJUSTMENT

The adjustment is for a gate that is over 300 pounds and 12 feet long or longer. While the gate is closing, instantly an "open" command is given as shown above; the clutch may slip a bit, max. of 1/4 to 3/4 of a turn (slippage depends on the weight of the gate). If it does not slip, then readjust the clutch.

IMPORTANT!
Installers are required to adhere to this procedure: The UL required Warning Signs must be installed in plain view and on both sides of each commercial gate installed. Each sign is made with fastening holes in each corner and should be permanently secured in a suitable manner. Also the warning sticker should be placed on the operator so it is clearly visible.

TOP


WARNING SIGNS

TWO-WAY ADJUSTABLE REVERSING SENSOR

The level of sensitivity has to do with the weight of the gate and the condition of installation.
Too sensitive =  if the gate stops or reverses by itself.
Not sensitive enough = if the gate hits an object and does not stop or reverse

CAUTION: If the power supply to the gate operator is less than 99 volts, adjust the alarm by turning the alarm adjustment counterclockwise enough to actuate the alarm when obstructed but not sensitive enough for false triggering to occur.

ADJUSTABLE TIMER

MASTER AND SLAVE WITH TIMER ON

 

TOP

MASTER AND SLAVE WITH TIMER OFF

PARTIAL MASTER/INDIVIDUAL CONTROL

PARTIAL MASTER/INDIVIDUAL CONTROL
IN ORDER FOR THE FOLLOWING OPERATION TO OCCUR, FOLLOW THE INSTRUCTIONS.
EXAMPLE: There is a double gate, the entry gate is to be opened with a radio transmitter 
and the exit gate
with a free exit loop. Only one safety loop system is to open both gates, and a fire 
department switch
should open both gates at the same time.
1. Connect the radio receiver to entry gate only.
2. Connect the exit loop to exit gate only.
3. Connect the safety loop to both entry and exit gates.
4. Connect the fire department switch to both entry and exit gates.

TOP


INSTRUCTIONS FOR OPTIONAL SYSTEMS

MASTER/SLAVE WITH OPTIONAL BOARD

SOLENOID CONNECTION WITH OPTIONAL BOARD

MAGLOCK WITH OPTIONAL BOARD

SOLENOID / MAGLOCK J3 CONNECTION

 

TOP

HOUSE ALARM / PROXIMITY SWITCH CONNECTIONS

OPTIONAL BUILT-IN LOOP DETECTORS

 

TOP

THREE PUSH BUTTON STATION

TERMINAL INPUT CONNECTIONS

SAFETY LOOP SYSTEM

 

TOP

CENTER LOOP SYSTEM

EXIT LOOP SYSTEM

ACCESS DOOR

EMERGENCY RELEASE

 

TOP

HOW TO REPLACE CONTROL BOARD

AUDIO ALARM

OPTIONAL DC-1000U BACK-UP

 

TOP

STOP BUTTON ALARM SHUT-OFF

UPHILL DRIVE WAY INSTALLATION

SECONDARY ENTRAPMENT WIRING

 

TOP

SECONDARY ENTRAPMENT MOUNTING

TROUBLE SHOOTING LED INFORMATION

PARTS LIST


 

Top

For God sent not his Son into the world to condemn the world; but that the world through him might be saved. John 3:17