APOLLO 7000 SLIDE GATE OPERATOR ![]() INSTALLATION MANUAL AND OWNER'S GUIDE *The model 633 and 634 control boards have been modified for a better troubleshooting convenience to our customer. The model 633/634 control board is now called the model 635/636 with new LED light read outs that help troubleshoot your problems. You just push a button to see what part of the control board is saying where the problem exist. IMPORTANT, READ ALL INSTRUCTIONS BEFORE ATTEMPTING INSTALLATION! SAFETY PRECAUTIONS (1) When servicing the operator or gate, always disconnect the battery. (2) Ensure that the gate caution sign is installed on the gate in a position where it can be easily seen. (3) All rollers and gears should be covered as a safety precaution. (4) A reversing edge switch is recommended on any slide gate where the possibility of pedestrian traffic exists or if an obstruction is encountered in the closing path of the gate. (5) If the opening direction presents a potential for hazard, an additional edge switch can be added to stop the gate. (6) Test all warning and reversing functions of your gate operator system at least once a month to insure safe operation.
1.) CONTROL BOX INSTALLATION ![]() Fig. 1-1 MOUNTING POSTS INSTALLATION
![]() Fig. 1-2 CONTROL BOX INSTALLATION 2.) MOUNTING GATE BRACKETS
3.) CHAIN INSTALLATION
![]() Fig. 3-1 CHAIN BOLT INSTALLATION D) Position gate so it is about halfway closed/open. Thread chain around drive and idler sprockets and pull towards front gate bracket (fig. 3-2). ![]() Fig. 3-2 CHAIN INSTALLATION E) Adjust chain to proper length then attach remaining chain-bolt to end of chain and bolt to front gate bracket. F) Check alignment of chain idler sprockets in both vertical and horizontal direction. G) Adjust nuts on eye bolts to remove excess chain slack (about 1" of slack for every 10 feet of chain). Do not over tighten chain. H) Attach hood. 4.) LIMIT ADJUSTMENTA) BE SURE THE HOOD COVERING THE DRIVE AND IDLER SPROCKETS IS SECURED. KEEP PERSONNEL AWAY FROM THE GATE WHILE TESTING. B) Connect battery (red-positive, black – negative). C) Push test button to activate gate. If gate starts opening, push button twice to stop and reverse gate. Once gate starts closing, push the test button to stop the gate within 3" of the desired close position. Disconnect battery. D) Mount one of the magnets on the short side of the chain just before the chain enters the hood. E) Mount the other magnet at a distance of the length of the gate opening less 15" from the first magnet. F) Reconnect battery and test limits. Re-adjust if necessary. We recommend that the battery be disconnected when changing limits. G) Once all adjustments have been completed, tack weld all u-bolts to prevent slipping. 5.) SETTING AUTOMATIC CLOSE Switch #1 on the set of red and white switches activates the automatic close when placed in the "on" position. Apollo slide gate operators are set at the factory for a left-handed closure (if you are standing from inside the property facing out, the gate closes to the left). If your gate closes to the right, you will have to change the following connections on the terminal strip: 1) Swap the white and orange wires (3 & 5)2) Swap the red and black wires (1 & 2) 6.) SOLAR PANEL INSTALLATION 1) Determine a suitable mounting location for the solar panel. The solar panel is shipped with 10 feet of cable. Additional cable is available if required. The panel should aim south in the northern hemisphere and north in the southern hemisphere. There should be no obstructions (trees, buildings etc.) that would limit the amount of sunlight that hits the surface of the solar panel. 2) Weld or bolt the solar panel bracket at the selected location to an existing structure. 3) Mount the solar panel to the bracket using the two ¼" bolts and nuts that are shipped on the panel 4) Feed the cable through the hole with a grommet on the side of the control box and connect to battery (red-positive, black-negative). You may need to cut the connection off and re-splice once inside the control box. 6.1 The PC Board is factory pre-programmed as follows:
6.2 The pot screw to adjust the current sense sensitivity (Automatic Reverse) is set at minimum sensitivity. See the drawing of circuit board to locate pot screw, if necessary. The pot screw to adjust the automatic close is set at about 20 seconds. It may be adjusted up to 70 seconds or turned off completely. See drawing of circuit board to locate Timer to Close Adjustment. PROGRAM SWITCHESThe program switches are the 9 switches located at the top right of the circuit board. Note: The standard factory settings are in bold lettering.
Note: The timer ranges may vary from board to board. CONTROL BOARD CONNECTIONS #1 Open Limit Input #2 Close Limit Input#3 Motor - Positive during open mode, Negative during close mode#4 Motor - Negative during open mode, Positive during open mode#5 Ground#6 Ground#7 Ground - battery negative#8 Battery +12 VDC 7 Pin Connectors#1 Edge 1 input There are an additional 3 connectors for GROUND, INPUT, & 12V. Each of these is fused for 2 amps max. The EMERGENCY BYPASS CONNECTOR is for use in situations when the control board is not operating correctly. Unplug the 8 pin white connector from the Master or Slave input and plug into the Emergency Bypass Connector. When the gate is open enough to get in or out, remove the plug. If the plug is not removed, the motor will stall and blow fuse F1.The model 7000 incorporates a mechanical release that is the preferred method of operating the gate manually.
![]()
SYMPTOM: Gate opens OK but after closing, opens back up. SYMPTOM: Gate doesn't move at all. SYMPTOM: Gate moves only a few feet, then stops. SYMPTOM: Gate will open using push button control board but not with
transmitter. SYMPTOM: Transmitter works, but not very far away. SYMPTOM: Gate randomly opens, closes, and stops for no reason. QUICK RELEASE for manual operation ![]() WARNING DISCONNECT BATTERY BEFORE RELEASING GATE TO RELEASE GATE – Pull quick release out and turn ¼ in either direction. Gate can now be manually opened or closed. TO REENGAGE – Turn quick release until it locks into place. Reconnect battery. TO RELEASE GATE – Pull quick release out and turn ¼ in either direction. Gate can now be manually opened or closed. TO REENGAGE – Turn quick release until it locks into place. Reconnect battery. |
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Revised:
November 06, 2007
. |